#REDIRECT [[Spindles and VFDs]]
Huangyang VFD
+
 
+
===To change settings:===
+
 
+
:#Press [PROGRAM]
+
:#Use arrow keys to change to program number your looking to change
+
:#Press [SET]
+
:#Use the arrow keys to change the value to appropriate value
+
:#Press [SET] to save the value
+
 
+
===Setting needed for galaxy series machines:===
+
 
+
:*PD001 – Source of Run Command –  0
+
:*PD002 – Source of Operating Frequency –  1
+
:*PD014 - Acceleration - 3
+
:*PD070 – Analog Input 0-10V –  0
+
:*PD144 – Rated Motor Revolution –  3000
+
 
+
===Displaying RPM instead of Hz:===
+
 
+
Press the arrow over key until the Rott light is illuminated
+
 
+
[[File:VFD_wiring_diagram.jpg|thumb|500px|left|alt=VFD Wiring|VFD Wiring Diagram]]
+
 
+
 
+
Sunfar VFD
+
 
+
Running:low noise runningF0.0 = 4 (or 3 if you want to test using the knob on the VFD) F1.7=1 F0.2=1001 (or 1000 if you want to test using the knob on VFD) F1.8=2 F0.4= 400 or 1000 set according your spindle F1.9=3 F0.5=10 F0.6=10 F0.11=0 F0.12=400 or 1000 set according your spindle F0.13=220 F1.3=400 or 1000 set according your spindle - See more at: http://www.automationtechnologiesinc.com/products-page/cnc-spindle/kl-vfd03-300w-mini-type-integrated-universal-inverter-vfd#sthash.scilFXlD.dpuf
+