| (14 intermediate revisions by one other user not shown) |
| Line 1: |
Line 1: |
| − | [[File:VFD_wiring_diagram.jpg|thumb|400px|left|alt=VFD Wiring|VFD Wiring Diagram]]
| + | #REDIRECT [[Spindles and VFDs]] |
| − | Huangyang VFD
| + | |
| − | | + | |
| − | [[Media:Huanyang_SL_Series_Manual.pdf | Huanyang VFD Manual]]
| + | |
| − | | + | |
| − | ===To change settings:===
| + | |
| − | | + | |
| − | :#Press [PROGRAM]
| + | |
| − | :#Use arrow keys to change to program number your looking to change
| + | |
| − | :#Press [SET]
| + | |
| − | :#Use the arrow keys to change the value to appropriate value
| + | |
| − | :#Press [SET] to save the value
| + | |
| − | | + | |
| − | ===Setting needed for galaxy series machines:===
| + | |
| − | | + | |
| − | :*PD001 – Source of Run Command – 0
| + | |
| − | :*PD002 – Source of Operating Frequency – 1
| + | |
| − | :*PD014 - Acceleration - 3
| + | |
| − | :*PD070 – Analog Input 0-10V – 0
| + | |
| − | :*PD144 – Rated Motor Revolution – 3000
| + | |
| − | | + | |
| − | ===Displaying RPM instead of Hz:===
| + | |
| − | | + | |
| − | Press the arrow over key until the Rott light is illuminated
| + | |
| − | | + | |
| − | | + | |
| − | | + | |
| − | | + | |
| − | | + | |
| − | | + | |
| − | | + | |
| − | | + | |
| − | | + | |
| − | | + | |
| − | | + | |
| − | | + | |
| − | <hr>
| + | |
| − | | + | |
| − | Sunfar VFD
| + | |
| − | | + | |
| − | [[Media:Sunfar_VFD.pdf | Sunfar VFD Manual]]
| + | |
| − | | + | |
| − | ===To change settings:===
| + | |
| − | | + | |
| − | :#Press [SET]
| + | |
| − | :#Use arrow keys to change to program number your looking to change
| + | |
| − | :#Press [SET]
| + | |
| − | :#Use the arrow keys to change the value to appropriate value
| + | |
| − | :#Press [SET] to save the value
| + | |
| − | :#Press [ESC] to exit programming mode
| + | |
| − | | + | |
| − | | + | |
| − | ===Setting needed for galaxy series machines:===
| + | |
| − | | + | |
| − | *:F0.0 = 1 (for 0-10V Control) or 3 (for knob control)
| + | |
| − | *:F0.2 = 1001 (for 0-10V Control) /1000 (for knob control)
| + | |
| − | *:F0.5 = 3 (Acceleration time)
| + | |
| − | *:F0.6 = 0 (Deceleration time)
| + | |
| − | *:F0.13 = 220 (Volts)
| + | |
| − | | + | |
| − | F1.3=400 or 1000 set according your spindle
| + | |
| − | F1.7=1
| + | |
| − | F1.8=2 F0.4= 400 or 1000 set according your spindle
| + | |
| − | F1.9=3
| + | |
| − | | + | |
| − | F0.12=400 or 1000 set according your spindle
| + | |