Actions

Difference between revisions of "VFDs"

From PROBOTIX :: wiki

(Split VFD content into separate pages and reorganize spindle/VFD pages)
 
(10 intermediate revisions by one other user not shown)
Line 1: Line 1:
[[File:VFD_wiring_diagram.jpg|thumb|400px|left|alt=Huanyang VFD Wiring|Huanyang VFD Wiring Diagram]]
+
#REDIRECT [[Spindles and VFDs]]
Huangyang VFD
+
 
+
[[Media:Huanyang_SL_Series_Manual.pdf | Huanyang VFD Manual]]
+
 
+
===To change settings:===
+
 
+
:#Press [PROGRAM]
+
:#Use arrow keys to change to program number your looking to change
+
:#Press [SET]
+
:#Use the arrow keys to change the value to appropriate value
+
:#Press [SET] to save the value
+
 
+
===Setting needed for galaxy series machines:===
+
 
+
:*PD001 – Source of Run Command –  0
+
:*PD002 – Source of Operating Frequency –  1
+
:*PD014 - Acceleration - 3
+
:*PD070 – Analog Input 0-10V –  0
+
:*PD144 – Rated Motor Revolution –  3000
+
 
+
===Displaying RPM instead of Hz:===
+
 
+
Press the arrow over key until the Rott light is illuminated
+
 
+
 
+
 
+
 
+
 
+
 
+
 
+
 
+
 
+
 
+
 
+
 
+
<hr>
+
 
+
Sunfar VFD
+
 
+
[[Media:Sunfar_VFD.pdf | Sunfar VFD Manual]]
+
 
+
===To change settings:===
+
 
+
:#Press [SET]
+
:#Use arrow keys to change to program number your looking to change
+
:#Press [SET]
+
:#Use the arrow keys to change the value to appropriate value
+
:#Press [SET] to save the value
+
:#Press [ESC] to exit programming mode
+
 
+
 
+
===Setting needed for galaxy series machines:===
+
 
+
:*F0.0 = 1 (for 0-10V Control) or 3 (for knob control)
+
:*F0.2 = 1000 (for panel [RUN] button)
+
:*F0.4= 400 (Spindle Frequency)
+
:*F0.5 = 3 (Acceleration time)
+
:*F0.6 = 0 (Deceleration time)
+
:*F0.12 = 400 (Basic Frequency)
+
:*F0.13 = 220 (Volts)
+
:*F1.3 = 400 (Max Frequency)
+
:*F1.7=1
+
:*F1.8=2
+
:*F1.9=3
+