| − | == Huangyang VFD ==
| + | #REDIRECT [[Spindles and VFDs]] |
| − | [[File:VFD_wiring_diagram.jpg|thumb|400px|alt=Huanyang VFD Wiring|Huanyang VFD Wiring Diagram]]
| + | |
| − | | + | |
| − | [[Media:Huanyang_SL_Series_Manual.pdf | Huanyang VFD Manual]]
| + | |
| − | | + | |
| − | ===To change settings:===
| + | |
| − | | + | |
| − | :#Press [PROGRAM]
| + | |
| − | :#Use arrow keys to change to program number your looking to change
| + | |
| − | :#Press [SET]
| + | |
| − | :#Use the arrow keys to change the value to appropriate value
| + | |
| − | :#Press [SET] to save the value
| + | |
| − | | + | |
| − | ===Setting needed for galaxy series machines:===
| + | |
| − | | + | |
| − | :*PD001 – Source of Run Command – 0
| + | |
| − | :*PD002 – Source of Operating Frequency – 1
| + | |
| − | :*PD014 - Acceleration - 3
| + | |
| − | :*PD070 – Analog Input 0-10V – 0
| + | |
| − | :*PD144 – Rated Motor Revolution – 3000
| + | |
| − | | + | |
| − | ===Displaying RPM instead of Hz:===
| + | |
| − | | + | |
| − | Press the arrow over key until the Rott light is illuminated
| + | |
| − | | + | |
| − | | + | |
| − | == Sunfar E300 VFD ==
| + | |
| − | [[Media:Sunfar_VFD.pdf | Sunfar E300 VFD Manual]]
| + | |
| − | | + | |
| − | ===To change settings:===
| + | |
| − | | + | |
| − | :#Press [SET]
| + | |
| − | :#Use arrow keys to change to program number your looking to change
| + | |
| − | :#Press [SET]
| + | |
| − | :#Use the arrow keys to change the value to appropriate value
| + | |
| − | :#Press [SET] to save the value
| + | |
| − | :#Press [ESC] to exit programming mode
| + | |
| − | | + | |
| − | | + | |
| − | ===Setting needed for galaxy series machines:===
| + | |
| − | | + | |
| − | :*F0.0 = 1 (for 0-10V Control) or 3 (for knob control)
| + | |
| − | :*F0.2 = 1000 (for panel [RUN] button)
| + | |
| − | :*F0.4= 400 (Spindle Frequency)
| + | |
| − | :*F0.5 = 5.0 (Acceleration time)
| + | |
| − | :*F0.12 = 400 (Basic Frequency)
| + | |
| − | :*F0.13 = 220 (Volts)
| + | |
| − | :*F1.3 = 400 (Max Frequency)
| + | |
| − | :*F1.7=1
| + | |
| − | :*F1.8=2
| + | |
| − | :*F1.9=3
| + | |
| − | | + | |
| − | | + | |
| − | == Sunfar E500 VFD ==
| + | |
| − | [[Media:SunfarE500.pdf | Sunfar E500 VFD Manual]]
| + | |
| − | | + | |
| − | ===To change settings:===
| + | |
| − | | + | |
| − | :#Press [SET]
| + | |
| − | :#Use arrow keys to change to program number your looking to change
| + | |
| − | :#Press [SET]
| + | |
| − | :#Use the arrow keys to change the value to appropriate value
| + | |
| − | :#Press [SET] to save the value
| + | |
| − | :#Press [ESC] to exit programming mode
| + | |
| − | | + | |
| − | | + | |
| − | ===Setting needed for galaxy series machines:===
| + | |
| − | | + | |
| − | :*F0.0 = 1 (for 0-10V Control) or 3 (for knob control)
| + | |
| − | :*F0.2 = 1001 (for panel [RUN] button)
| + | |
| − | :*F0.4= 400 (Spindle Frequency)
| + | |
| − | :*F0.5 = 5.0 (Acceleration time)
| + | |
| − | :*F0.11 = 0 (Torque Boost)
| + | |
| − | :*F0.12 = 400 (Basic Frequency)
| + | |
| − | :*F0.13 = 220 (Volts)
| + | |
| − | :*F1.00 = 0.4 (AI Lower Limit)
| + | |
| − | :*F1.01 = 10 (AI Upper Limit)
| + | |
| − | :*F1.03 = 0 (Min Freq)
| + | |
| − | :*F1.04 = 400 (Max Freq)
| + | |
| − | :*F1.08 = 11 (Terminal 1 Function)
| + | |