== Huangyang VFD ==
+
[[File:VFD_wiring_diagram.jpg|thumb|400px|alt=Huanyang VFD Wiring|Huanyang VFD Wiring Diagram]]
+
 
+
[[Media:Huanyang_SL_Series_Manual.pdf | Huanyang VFD Manual]]
+
 
+
===To change settings:===
+
# Press [PROGRAM]
+
# Use arrow keys to change to program number your looking to change
+
# Press [SET]
+
# Use the arrow keys to change the value to appropriate value
+
# Press [SET] to save the value
+
 
+
===Setting needed for galaxy series machines:===
+
* PD001 – Source of Run Command –  0
+
* PD002 – Source of Operating Frequency –  1
+
* PD014 - Acceleration - 3
+
* PD070 – Analog Input 0-10V –  0
+
* PD144 – Rated Motor Revolution –  3000
+
 
+
===Displaying RPM instead of Hz:===
+
Press the arrow over key until the Rott light is illuminated
+
 
+
 
+
== Sunfar E300 VFD ==
+
[[File:VFD_Sunfar_E300.jpg|thumb|400px|alt=Sunfar E300 VFD Wiring|Sunfar E300 VFD Wiring Diagram]]
+
[[Media:Sunfar_VFD.pdf | Sunfar E300 VFD Manual]]
+
 
+
===To change settings:===
+
# Press [SET]
+
# Use arrow keys to change to program number your looking to change
+
# Press [SET]
+
# Use the arrow keys to change the value to appropriate value
+
# Press [SET] to save the value
+
# Press [ESC] to exit programming mode
+
 
+
 
+
===Setting needed for galaxy series machines:===
+
* F0.00 = 1 (for 0-10V Control) or 3 (for knob control)
+
* F0.02 = 1000 (for panel [RUN] button)
+
* F0.04= 400 (Spindle Frequency)
+
* F0.05 = 5.0 (Acceleration time)
+
* F0.12 = 400 (Basic Frequency)
+
* F0.13 = 220 (Volts)
+
* F1.03 = 400 (Max Frequency)
+
* F1.07=1
+
* F1.08=2
+
* F1.09=3
+
 
+
== Sunfar E500 VFD ==
+
[[File:VFD_Sunfar_E500.jpg|thumb|400px|alt=Sunfar E500 VFD Wiring|Sunfar E500 VFD Wiring Diagram]]
+
[[Media:SunfarE500.pdf | Sunfar E500 VFD Manual]]
+
 
+
===To change settings:===
+
# Press [SET]
+
# Use arrow keys to change to program number your looking to change
+
# Press [SET]
+
# Use the arrow keys to change the value to appropriate value
+
# Press [SET] to save the value
+
# Press [ESC] to exit programming mode
+
 
+
 
+
===Setting needed for galaxy series machines:===
+
* F0.00 = 1 (for 0-10V Control) or 3 (for knob control)
+
* F0.02 = 1001 (for panel [RUN] button)
+
* F0.04= 400 (Spindle Frequency)
+
* F0.05 = 5.0 (Acceleration time)
+
* F0.11 = 0 (Torque Boost)
+
* F0.12 = 400 (Basic Frequency)
+
* F0.13 = 220 (Volts)
+
* F1.00 = 0.4 (AI Lower Limit)
+
* F1.01 = 10 (AI Upper Limit)
+
* F1.03 = 0 (Min Freq)
+
* F1.04 = 400 (Max Freq)
+
* F1.08 = 11 (Terminal 1 Function)
+
 
+
 
+
== H100 VFD ==
+
H100_VFD_wiring_diagram.jpg
+