Actions

Difference between revisions of "VFDs"

From PROBOTIX :: wiki

(==To change settings:=)
Line 1: Line 1:
== ==To change settings:===
+
===To change settings:===
  
 
:#Press [PROGRAM]
 
:#Press [PROGRAM]

Revision as of 10:39, 31 August 2015

To change settings:

  1. Press [PROGRAM]
  2. Use arrow keys to change to program number your looking to change
  3. Press [SET]
  4. Use the arrow keys to change the value to appropriate value
  5. Press [SET] to save the value

Setting needed for galaxy series machines:

  • PD001 – Source of Run Command – 0
  • PD002 – Source of Operating Frequency – 1
  • PD070 – Analog Input 0-10V – 0
  • PD144 – Rated Motor Revolution – 3000

Displaying RPM instead of Hz:

Press the arrow over key until the Rott light is illuminated

VFD Wiring