Sunfar E500 VFD

From PROBOTIX :: wiki

Sunfar E500 VFD

Sunfar E500 VFD Wiring
Sunfar E500 VFD Wiring Diagram

Sunfar E500 VFD Manual

To change settings

  1. Press [SET]
  2. Use arrow keys to change to program number your looking to change
  3. Press [SET]
  4. Use the arrow keys to change the value to appropriate value
  5. Press [SET] to save the value
  6. Press [ESC] to exit programming mode

Settings needed for Galaxy series machines

  • F0.00 = 1 (for 0-10V Control) or 3 (for knob control)
  • F0.02 = 1001 (for panel [RUN] button)
  • F0.04= 400 (Spindle Frequency)
  • F0.05 = 5.0 (Acceleration time)
  • F0.11 = 0 (Torque Boost)
  • F0.12 = 400 (Basic Frequency)
  • F0.13 = 220 (Volts)
  • F1.00 = 0.4 (AI Lower Limit)
  • F1.01 = 10 (AI Upper Limit)
  • F1.03 = 0 (Min Freq)
  • F1.04 = 400 (Max Freq)
  • F1.08 = 11 (Terminal 1 Function)